{"id":3784,"date":"2026-05-13T10:00:00","date_gmt":"2026-05-13T08:00:00","guid":{"rendered":"https:\/\/fondazionemichelangelo.org\/?p=3784"},"modified":"2026-04-21T15:47:45","modified_gmt":"2026-04-21T13:47:45","slug":"lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico","status":"publish","type":"post","link":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/","title":{"rendered":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"3784\" class=\"elementor elementor-3784 elementor-3779\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-02149d2 elementor-hidden-tablet elementor-hidden-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"02149d2\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e54763c\" data-id=\"e54763c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d53be86 elementor-widget elementor-widget-spacer\" data-id=\"d53be86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f66be8e elementor-hidden-tablet elementor-hidden-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f66be8e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2e5ded1\" data-id=\"2e5ded1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4cdc392 elementor-widget elementor-widget-heading\" data-id=\"4cdc392\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7270382 elementor-widget elementor-widget-heading\" data-id=\"7270382\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0acc446 elementor-widget elementor-widget-post-info\" data-id=\"0acc446\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-eb56c14 elementor-inline-item\" itemprop=\"datePublished\">\n\t\t\t\t\t\t<a href=\"https:\/\/fondazionemichelangelo.org\/it\/2026\/05\/13\/\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-date\">\n\t\t\t\t\t\t\t\t\t\t<time>Maggio 13, 2026<\/time>\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9db4eb4 elementor-reverse-tablet elementor-reverse-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9db4eb4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-0f24e54\" data-id=\"0f24e54\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3f66215 elementor-hidden-tablet elementor-hidden-mobile elementor-widget elementor-widget-text-editor\" data-id=\"3f66215\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I risultati dello studio Mammography Screening with Artificial Intelligence (MASAI), <a href=\"https:\/\/www.thelancet.com\/journals\/lancet\/article\/PIIS0140-6736(25)02464-X\/abstract\" target=\"_blank\" rel=\"noopener\">recentemente pubblicati su The Lancet<\/a>, dimostrano che lo screening mammografico supportato dall&#8217;intelligenza artificiale (IA) ha esiti pi\u00f9 favorevoli rispetto al doppio screening standard, in termini di incidenza di tumori di intervallo e tumori di intervallo dalle caratteristiche sfavorevoli.<\/p><p>Lo studio MASAI \u00e8 uno studio randomizzato, controllato, di non inferiorit\u00e0, in singolo cieco e basato sulla popolazione, che ha avuto come tema l&#8217;accuratezza dello screening ed \u00e8 stato integrato nel programma svedese di screening per il tumore al seno, all\u2019interno del quale le partecipanti sono state assegnate in modo casuale a uno screening mammografico supportato dall&#8217;IA o a una doppia lettura standard senza IA. Un totale di 105.934 donne sono state randomizzate nel gruppo di intervento o di controllo; nel gruppo supportato dall&#8217;IA, gli esami con punteggi di rischio dall\u2019IA bassi sono stati indirizzati a una singola lettura, mentre quelli con un punteggio di rischio IA elevato sono stati sottoposti a doppia lettura, con l&#8217;IA utilizzata come supporto diagnostico per i radiologi. I tassi di tumori d\u2019intervallo sono stati rispettivamente di 1,55 e 1,76 ogni 1000 partecipanti nel gruppo di intervento con IA e nel gruppo di controllo. Il gruppo sottoposto a screening supportato dall&#8217;IA ha presentato un numero inferiore di tumori d\u2019intervallo invasivi, T2+ o non luminali A rispetto al gruppo di controllo; la sensibilit\u00e0 \u00e8 risultata stabilmente pi\u00f9 elevata nei gruppi diversi per et\u00e0 e densit\u00e0 del seno, oltre che per il tumore invasivo, ma non per il carcinoma in situ. Gli autori concludono che \u00ablo screening mammografico supportato dall&#8217;IA ha mostrato risultati costantemente favorevoli rispetto alla doppia lettura standard, con un tasso di tumori di intervallo non inferiore, un numero inferiore di tumori di intervallo con caratteristiche sfavorevoli, una sensibilit\u00e0 maggiore e la stessa specificit\u00e0, riducendo al contempo il carico di lavoro per la lettura dello screening. Questi risultati implicano che lo screening mammografico supportato dall&#8217;IA pu\u00f2 migliorare efficacemente le prestazioni dello screening rispetto alla doppia lettura standard e pu\u00f2 essere considerato per l&#8217;implementazione nella pratica clinica\u00bb.    <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-0c9aa07\" data-id=\"0c9aa07\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9783214 elementor-hidden-desktop elementor-widget elementor-widget-heading\" data-id=\"9783214\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico <\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-263dcb7 elementor-hidden-desktop elementor-widget elementor-widget-heading\" data-id=\"263dcb7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2e14ce elementor-hidden-desktop elementor-widget elementor-widget-post-info\" data-id=\"c2e14ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-eb56c14 elementor-inline-item\" itemprop=\"datePublished\">\n\t\t\t\t\t\t<a href=\"https:\/\/fondazionemichelangelo.org\/it\/2026\/05\/13\/\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-date\">\n\t\t\t\t\t\t\t\t\t\t<time>Maggio 13, 2026<\/time>\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7d6a553 elementor-widget elementor-widget-image\" data-id=\"7d6a553\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer-1024x768.jpg\" class=\"attachment-large size-large wp-image-2391\" alt=\"\" srcset=\"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer-1024x768.jpg 1024w, https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer-300x225.jpg 300w, https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer-768x576.jpg 768w, https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer-1536x1152.jpg 1536w, https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer.jpg 2000w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-778e919 elementor-hidden-desktop elementor-widget elementor-widget-text-editor\" data-id=\"778e919\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I risultati dello studio Mammography Screening with Artificial Intelligence (MASAI), <a href=\"https:\/\/www.thelancet.com\/journals\/lancet\/article\/PIIS0140-6736(25)02464-X\/abstract\" target=\"_blank\" rel=\"noopener\">recentemente pubblicati su The Lancet<\/a>, dimostrano che lo screening mammografico supportato dall&#8217;intelligenza artificiale (IA) ha esiti pi\u00f9 favorevoli rispetto al doppio screening standard, in termini di incidenza di tumori di intervallo e tumori di intervallo dalle caratteristiche sfavorevoli.<\/p><p>Lo studio MASAI \u00e8 uno studio randomizzato, controllato, di non inferiorit\u00e0, in singolo cieco e basato sulla popolazione, che ha avuto come tema l&#8217;accuratezza dello screening ed \u00e8 stato integrato nel programma svedese di screening per il tumore al seno, all\u2019interno del quale le partecipanti sono state assegnate in modo casuale a uno screening mammografico supportato dall&#8217;IA o a una doppia lettura standard senza IA. Un totale di 105.934 donne sono state randomizzate nel gruppo di intervento o di controllo; nel gruppo supportato dall&#8217;IA, gli esami con punteggi di rischio dall\u2019IA bassi sono stati indirizzati a una singola lettura, mentre quelli con un punteggio di rischio IA elevato sono stati sottoposti a doppia lettura, con l&#8217;IA utilizzata come supporto diagnostico per i radiologi. I tassi di tumori d\u2019intervallo sono stati rispettivamente di 1,55 e 1,76 ogni 1000 partecipanti nel gruppo di intervento con IA e nel gruppo di controllo. Il gruppo sottoposto a screening supportato dall&#8217;IA ha presentato un numero inferiore di tumori d\u2019intervallo invasivi, T2+ o non luminali A rispetto al gruppo di controllo; la sensibilit\u00e0 \u00e8 risultata stabilmente pi\u00f9 elevata nei gruppi diversi per et\u00e0 e densit\u00e0 del seno, oltre che per il tumore invasivo, ma non per il carcinoma in situ. Gli autori concludono che \u00ablo screening mammografico supportato dall&#8217;IA ha mostrato risultati costantemente favorevoli rispetto alla doppia lettura standard, con un tasso di tumori di intervallo non inferiore, un numero inferiore di tumori di intervallo con caratteristiche sfavorevoli, una sensibilit\u00e0 maggiore e la stessa specificit\u00e0, riducendo al contempo il carico di lavoro per la lettura dello screening. Questi risultati implicano che lo screening mammografico supportato dall&#8217;IA pu\u00f2 migliorare efficacemente le prestazioni dello screening rispetto alla doppia lettura standard e pu\u00f2 essere considerato per l&#8217;implementazione nella pratica clinica\u00bb.    <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9b08486 elementor-hidden-tablet elementor-hidden-mobile elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9b08486\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-23c6e0c\" data-id=\"23c6e0c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b33e9e1 elementor-widget elementor-widget-spacer\" data-id=\"b33e9e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"spacer.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-spacer\">\n\t\t\t<div class=\"elementor-spacer-inner\"><\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard<\/p>\n","protected":false},"author":3,"featured_media":2391,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[24],"tags":[],"class_list":["post-3784","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-notizie-e-aggiornamenti"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.2.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"admin 1\"\/>\n\t<link rel=\"canonical\" href=\"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.2.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"it_IT\" \/>\n\t\t<meta property=\"og:site_name\" content=\"Fondazione Michelangelo -\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo\" \/>\n\t\t<meta property=\"og:description\" content=\"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2022\/11\/Progetto-senza-titolo.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2022\/11\/Progetto-senza-titolo.png\" \/>\n\t\t<meta property=\"og:image:width\" content=\"1080\" \/>\n\t\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-05-13T08:00:00+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-04-21T13:47:45+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo\" \/>\n\t\t<meta name=\"twitter:description\" content=\"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2022\/11\/Progetto-senza-titolo.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#blogposting\",\"name\":\"L\\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo\",\"headline\":\"L\\u2019IA a confronto con la doppia lettura standard per lo screening mammografico\",\"author\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/author\\\/admin1\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/wp-content\\\/uploads\\\/2023\\\/09\\\/screnning-breast-cancer.jpg\",\"width\":2000,\"height\":1500,\"caption\":\"Mammogram snapshot of breasts of a female patient on the monitor with undergoing mammography test on the background. Mammography test at the hospital. Medical equipment.\"},\"datePublished\":\"2026-05-13T10:00:00+02:00\",\"dateModified\":\"2026-04-21T15:47:45+02:00\",\"inLanguage\":\"it-IT\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#webpage\"},\"articleSection\":\"Notizie e aggiornamenti, Optional\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/category\\\/notizie-e-aggiornamenti\\\/#listItem\",\"name\":\"Notizie e aggiornamenti\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/category\\\/notizie-e-aggiornamenti\\\/#listItem\",\"position\":2,\"name\":\"Notizie e aggiornamenti\",\"item\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/category\\\/notizie-e-aggiornamenti\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#listItem\",\"name\":\"L\\u2019IA a confronto con la doppia lettura standard per lo screening mammografico\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#listItem\",\"position\":3,\"name\":\"L\\u2019IA a confronto con la doppia lettura standard per lo screening mammografico\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/category\\\/notizie-e-aggiornamenti\\\/#listItem\",\"name\":\"Notizie e aggiornamenti\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/#organization\",\"name\":\"Fondazione Michelangelo\",\"description\":\"Promuoviamo la ricerca scientifica in oncologia, con l'obiettivo di migliorare le opzioni di trattamento per i pazienti, collaborando con associazioni e professionisti del settore.\",\"url\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/wp-content\\\/uploads\\\/2023\\\/01\\\/immagine-evidenza-fm.png\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#organizationLogo\",\"width\":1200,\"height\":675},\"image\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/author\\\/admin1\\\/#author\",\"url\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/author\\\/admin1\\\/\",\"name\":\"admin 1\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9744a5b02beb7a6cb027c368f8a9ba8a800a8ff603b5fad54fcf92b808333d81?s=96&d=mm&r=g\",\"width\":96,\"height\":96,\"caption\":\"admin 1\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#webpage\",\"url\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/\",\"name\":\"L\\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo\",\"description\":\"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\\u00f9 favorevoli con l\\u2019uso dell\\u2019IA per lo screening mammografico rispetto alla doppia lettura standard\",\"inLanguage\":\"it-IT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/author\\\/admin1\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/author\\\/admin1\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/wp-content\\\/uploads\\\/2023\\\/09\\\/screnning-breast-cancer.jpg\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#mainImage\",\"width\":2000,\"height\":1500,\"caption\":\"Mammogram snapshot of breasts of a female patient on the monitor with undergoing mammography test on the background. Mammography test at the hospital. Medical equipment.\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/notizie-e-aggiornamenti\\\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\\\/#mainImage\"},\"datePublished\":\"2026-05-13T10:00:00+02:00\",\"dateModified\":\"2026-04-21T15:47:45+02:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/\",\"name\":\"Fondazione Michelangelo\",\"inLanguage\":\"it-IT\",\"publisher\":{\"@id\":\"https:\\\/\\\/fondazionemichelangelo.org\\\/it\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo","description":"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard","canonical_url":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#blogposting","name":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo","headline":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico","author":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/author\/admin1\/#author"},"publisher":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer.jpg","width":2000,"height":1500,"caption":"Mammogram snapshot of breasts of a female patient on the monitor with undergoing mammography test on the background. Mammography test at the hospital. Medical equipment."},"datePublished":"2026-05-13T10:00:00+02:00","dateModified":"2026-04-21T15:47:45+02:00","inLanguage":"it-IT","mainEntityOfPage":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#webpage"},"isPartOf":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#webpage"},"articleSection":"Notizie e aggiornamenti, Optional"},{"@type":"BreadcrumbList","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/fondazionemichelangelo.org\/it\/#listItem","position":1,"name":"Home","item":"https:\/\/fondazionemichelangelo.org\/it\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fondazionemichelangelo.org\/it\/category\/notizie-e-aggiornamenti\/#listItem","name":"Notizie e aggiornamenti"}},{"@type":"ListItem","@id":"https:\/\/fondazionemichelangelo.org\/it\/category\/notizie-e-aggiornamenti\/#listItem","position":2,"name":"Notizie e aggiornamenti","item":"https:\/\/fondazionemichelangelo.org\/it\/category\/notizie-e-aggiornamenti\/","nextItem":{"@type":"ListItem","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#listItem","name":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico"},"previousItem":{"@type":"ListItem","@id":"https:\/\/fondazionemichelangelo.org\/it\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#listItem","position":3,"name":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico","previousItem":{"@type":"ListItem","@id":"https:\/\/fondazionemichelangelo.org\/it\/category\/notizie-e-aggiornamenti\/#listItem","name":"Notizie e aggiornamenti"}}]},{"@type":"Organization","@id":"https:\/\/fondazionemichelangelo.org\/it\/#organization","name":"Fondazione Michelangelo","description":"Promuoviamo la ricerca scientifica in oncologia, con l'obiettivo di migliorare le opzioni di trattamento per i pazienti, collaborando con associazioni e professionisti del settore.","url":"https:\/\/fondazionemichelangelo.org\/it\/","logo":{"@type":"ImageObject","url":"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/01\/immagine-evidenza-fm.png","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#organizationLogo","width":1200,"height":675},"image":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/fondazionemichelangelo.org\/it\/author\/admin1\/#author","url":"https:\/\/fondazionemichelangelo.org\/it\/author\/admin1\/","name":"admin 1","image":{"@type":"ImageObject","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/9744a5b02beb7a6cb027c368f8a9ba8a800a8ff603b5fad54fcf92b808333d81?s=96&d=mm&r=g","width":96,"height":96,"caption":"admin 1"}},{"@type":"WebPage","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#webpage","url":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/","name":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo","description":"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard","inLanguage":"it-IT","isPartOf":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/#website"},"breadcrumb":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#breadcrumblist"},"author":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/author\/admin1\/#author"},"creator":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/author\/admin1\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2023\/09\/screnning-breast-cancer.jpg","@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#mainImage","width":2000,"height":1500,"caption":"Mammogram snapshot of breasts of a female patient on the monitor with undergoing mammography test on the background. Mammography test at the hospital. Medical equipment."},"primaryImageOfPage":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/#mainImage"},"datePublished":"2026-05-13T10:00:00+02:00","dateModified":"2026-04-21T15:47:45+02:00"},{"@type":"WebSite","@id":"https:\/\/fondazionemichelangelo.org\/it\/#website","url":"https:\/\/fondazionemichelangelo.org\/it\/","name":"Fondazione Michelangelo","inLanguage":"it-IT","publisher":{"@id":"https:\/\/fondazionemichelangelo.org\/it\/#organization"}}]},"og:locale":"it_IT","og:site_name":"Fondazione Michelangelo -","og:type":"article","og:title":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo","og:description":"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard","og:url":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/","og:image":"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2022\/11\/Progetto-senza-titolo.png","og:image:secure_url":"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2022\/11\/Progetto-senza-titolo.png","og:image:width":1080,"og:image:height":1080,"article:published_time":"2026-05-13T08:00:00+00:00","article:modified_time":"2026-04-21T13:47:45+00:00","twitter:card":"summary_large_image","twitter:title":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico - Fondazione Michelangelo","twitter:description":"I risultati dello studio svedese MASAI mostrano esiti stabilmente pi\u00f9 favorevoli con l\u2019uso dell\u2019IA per lo screening mammografico rispetto alla doppia lettura standard","twitter:image":"https:\/\/fondazionemichelangelo.org\/wp-content\/uploads\/2022\/11\/Progetto-senza-titolo.png"},"aioseo_meta_data":{"post_id":"3784","title":null,"description":null,"keywords":null,"keyphrases":{"focus":{"keyphrase":"","score":0,"analysis":{"keyphraseInTitle":{"score":0,"maxScore":9,"error":1}}},"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":"","og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"BlogPosting","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":"-1","robots_max_videopreview":"-1","robots_max_imagepreview":"large","priority":null,"frequency":"default","local_seo":null,"breadcrumb_settings":null,"limit_modified_date":false,"ai":{"faqs":[],"keyPoints":[],"schemas":[],"titles":[],"descriptions":[],"socialPosts":{"email":[],"linkedin":[],"twitter":[],"facebook":[],"instagram":[]}},"created":"2026-04-17 09:03:47","updated":"2026-05-13 10:17:52","seo_analyzer_scan_date":null,"focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fondazionemichelangelo.org\/it\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/fondazionemichelangelo.org\/it\/category\/notizie-e-aggiornamenti\/\" title=\"Notizie e aggiornamenti\">Notizie e aggiornamenti<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tL\u2019IA a confronto con la doppia lettura standard per lo screening mammografico\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/fondazionemichelangelo.org\/it\/"},{"label":"Notizie e aggiornamenti","link":"https:\/\/fondazionemichelangelo.org\/it\/category\/notizie-e-aggiornamenti\/"},{"label":"L\u2019IA a confronto con la doppia lettura standard per lo screening mammografico","link":"https:\/\/fondazionemichelangelo.org\/it\/notizie-e-aggiornamenti\/lia-a-confronto-con-la-doppia-lettura-standard-per-lo-screening-mammografico\/"}],"_links":{"self":[{"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/posts\/3784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/comments?post=3784"}],"version-history":[{"count":1,"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/posts\/3784\/revisions"}],"predecessor-version":[{"id":3785,"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/posts\/3784\/revisions\/3785"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/media\/2391"}],"wp:attachment":[{"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/media?parent=3784"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/categories?post=3784"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/fondazionemichelangelo.org\/it\/wp-json\/wp\/v2\/tags?post=3784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}